Here is only a suggestion: Reward Points function (demo function). To use real Reward Points, you need a 3rd party Shopify App.
Your items may arrive sooner than the estimated delivery date. Ralph Lauren reserves the right to send packages via other shipping methods based on the shipping destination as long as orders will still arrive within the arrival times outlined on RalphLauren.com.
When you choose the Economy delivery option, packages are delivered Monday through Saturday 8 AM to 4:30 PM. Orders sent by Fast, 2-Business-Day or Next-Day shipping methods are delivered Monday through Friday from 8 AM to 4:30 PM.
We recommend choosing Fast or Next-Day delivery if you are shipping your package to a business address. You will be asked to provide a telephone number on the shipping page of checkout, which is important in the event the courier needs to arrange a delivery time with you.
You will also be asked to provide an email address, to which we will send confirmation that your order was placed.
Product information:
Product features:
1. Display parameters: blood oxygen SPO2 value, pulse PR value, blood oxygen bar graph, pulse waveform, PI (perfusion index), respiratory rate monitoring parameters
2. Display screen: The product adopts a blue and yellow dual color OLED screen display
3. Display method: Four directions
4. Energy saving: The product has low power consumption and is equipped with two AAA batteries that can last for more than 40 hours of use
5. Voltage warning: There is a low voltage warning prompt when the battery voltage is too low and may affect normal use
6. Automatic shutdown: When there is no signal generated, the product will automatically shut down after 8 seconds
7. Advantages: Integrating blood oxygen probe and processing display module, the product is simple to use, low power consumption, small in size, light in weight, and easy to carry
★ Product parameters:
Measurement range of blood oxygen saturation: 70%~99%
Pulse rate measurement range: 30BPM~240BPM
Measurement accuracy of blood oxygen saturation: ± 2% within the range of 70%~99%, ≤ 70% undefined
Pulse rate measurement accuracy: ± 1BPM or ± 1% of the measured value (whichever is higher) Blood oxygen saturation resolution: Blood oxygen saturation ± 1%
Blood flow perfusion index: ≥ 0.2%, ± 0.1%
Power consumption: less than 30mA
Automatic shutdown: When there is no finger inserted, it will automatically shut down within 8 seconds
Usage temperature: 5 ℃~40 ℃ Storage humidity: 15%~80%
10%~80% storage atmospheric pressure during operation: 70Kpa~106Kpa
Battery model: 2 * 1.5V (2 AAA alkaline batteries, product does not include batteries)
Material: ABS+PC